How do you winterise a garden irrigation system, and restart it in spring?

Last verified: 2026-11-15

What Rain Bird and Gardena say about draining sprinkler and drip lines before frost, putting the controller or tap timer to sleep for winter, and restarting the system safely in spring.

The short answer

If your garden gets frost, shut off the water to the irrigation system before the first freeze, get the water out of the pipes, valves and heads, and switch the controller to its rain or off mode. Rain Bird says it is advisable to winterise in a freezing climate, and names three ways to drain: manual drain valves, automatic drain valves, or blowing the lines out with compressed air. Battery tap timers come indoors: Gardena's Water Control manual says the unit is not frost-proof below 4 °C. In spring, check the soil has thawed, close the drain valves, and open the main valve slowly.

If your garden never freezes, none of the draining is needed. The spring check-up still is.

Step 1: shut off and protect the supply

Rain Bird's homeowner page starts with the main shut-off valve for the irrigation system: close it, and wrap it in insulation (foam tape and a plastic bag) so the valve itself does not freeze. Any pipe above ground should be insulated too. Above-ground valves and backflow preventers get the same treatment, without blocking the air vents and drain outlets on the backflow preventer.

Step 2: put the controller to sleep

Most controllers have a rain mode that stops signals to the valves while keeping the clock and programs, according to Rain Bird. Cutting the power also works, but then you reprogram in spring.

Rain Bird adds one caution that matters: if the controller also starts a pump, rain mode or off is not enough, because a power surge or outage can return some timers to automatic mode and run the pump dry. Its winterisation guide says to unplug indoor timers in that case, and for outdoor hard-wired timers to disconnect the common wire(s) to the pump start relay and valves after switching off the circuit breaker. If you are not comfortable working on the wiring, that is a job for an electrician or irrigation installer.

Step 3: get the water out

Rain Bird's guide describes three methods, and you may need more than one.

  • Manual drain valves: fitted at the lowest point of the mainline (and at every other low point). Close the main shut-off, open one zone valve to release the pressure, then open the drain valve slowly. Wear eye protection: the drain is under pressure until you relieve it.
  • Automatic drain valves: spring-loaded valves at the low points of the lines after the zone valves, which drain every time the system shuts off. Rain Bird says they must not be fitted on the mainline. Gardena's underground Drain Valve works the same way, opening when pressure falls below about 0.2 bar, and Gardena says to fit it at the lowest point, bedded in washed coarse gravel.
  • Compressed air blow-out: forces the water out through every pipe, valve and head. This is the one to be careful with (see below).

Gravity draining does not empty the valves themselves. Rain Bird says valves that are not blown out with air need to be opened up and drained, or for some manual valves simply left open over winter.

For Gardena's above-ground Pipeline and Sprinkler System, Gardena sells a Drain Valve Set that pushes the water out with an ordinary bicycle pump or an air compressor.

If you blow the lines out with air

Rain Bird's limits are specific:

  1. Air pressure must not exceed 50 psi (about 3.4 bar), set with a pressure regulator on the compressor. A compressor delivering 10 to 25 cubic feet per minute is needed for volume; small shop compressors may not be enough.
  2. Never run the compressor without at least one zone valve open, from start to shut-down.
  3. Do not blow any one zone for more than 2 minutes at a time: the heat can damage pipes, and sprinklers with plastic gears rely on water for lubrication.
  4. Go round the zones two or more times until only a fine mist comes out of the heads.
  5. Do not stand over pipes, valves or heads while blowing out, and wear eye protection.

Rain Bird says this is something irrigation contractors usually offer, often bundled with the spring start-up, and recommends calling one if you do not have the right compressor.

Tap timers and drip systems

A battery timer on an outdoor tap is the most common set-up in a small garden, and it is the easiest part to forget. Gardena's manual for its Water Control Easy and Basic timers says the product is not frost-proof below 4 °C, and that it should be stored in a dry, frost-free place with the batteries removed. The same manual puts battery life at about one season, so fresh batteries in spring are sensible.

Spring start-up

From Rain Bird's spring tune-up checklist:

  • Wait for the ground to thaw. Starting while the soil is frozen can damage pipes. Rain Bird's test is a spade: the soil should be frost-free 12 inches (about 30 cm) down.
  • Close every manual drain valve before turning any water on.
  • Open the main valve slowly, so the pipes fill gradually. A fast opening causes water hammer, which can burst pipes and damage valves.
  • Check the pressure. Rain Bird gives a typical operating range of 40 to 65 psi (about 2.8 to 4.5 bar); above that a pressure regulator may be needed, and misting heads are a sign the pressure is too high.
  • Check the controller: date, time and programs. Rain Bird suggests replacing the controller's backup battery every 6 months.
  • Inspect heads, nozzles and valves for debris, burial, cracks and leaks. Soggy or muddy patches can point to a leaking valve.

Before you rely on this

This reflects Rain Bird's North American homeowner guides (in psi and inches) and Gardena's own product pages and manual. Hunter's spring start-up page was not readable for this guide. Your pump, backflow preventer and controller each have their own manual, and Rain Bird itself says to check those manufacturers' winterisation instructions. If you are unsure, an irrigation installer can do both the autumn drain and the spring start-up.

Track it in Epimeleia

Add your irrigation system as an item with its controller and timer manuals attached, then set two reminders: one before your usual first frost to drain and shut down, and one in spring to restart, with your zone count and drain-valve locations in the notes.

Sources

Put this date somewhere it will find you

Epimeleia keeps every warranty, service interval and renewal for everything you own, and tells you before the date arrives instead of after.

Start free